Skip to main content
Stainless Steel
Market

Grade dossier

S32760 Super Duplex Stainless Steel with Copper and Tungsten

A copper- and tungsten-bearing super duplex grade developed for aggressive chloride, seawater and sour-service applications requiring high strength.

Open grade data

Identity before substitution

Define the grade, product and condition together

A familiar grade name is not a complete purchase specification. Product form, controlling standard, dimensions, condition, finish, certification and service environment determine whether the delivered material is suitable.

MicrostructureFerritic-austenitic super duplex
UNS identityS32760
PRE guidancetypically about 42
Common comparisonS32750; they are separate UNS grades

Composition control

ASTM A240/A240M flat-product chemistry

Limits are not heat analysis targets

The table summarizes grade limits commonly used for plate, sheet and strip. Pipe, tube, bar, forgings and cast products can be governed by different specifications. Always place the product standard and edition on the purchase order.

C0.030 max
Mn1.00 max
Si1.00 max
P0.030 max
S0.010 max
Cr24.00-26.00
Ni6.00-8.00
Mo3.00-4.00
N0.20-0.30
Cu0.50-1.00
W0.50-1.00

Properties with context

Minimums, typical indicators and delivered condition

Specified annealed flat-product values

Tensile strength750 MPa min
0.2% yield strength550 MPa min
Elongation25% min
Hardness310 HBW max reference

Selection indicators

Densityabout 7.8 g/cm3
Alloy distinctionCu and W differentiate S32760 from S32750
Strengthhigh; use exact product-form values
Temperatureobserve duplex code and phase-stability limits

Values depend on product form, thickness, test orientation, condition and governing edition. Use the mill test certificate and the purchase specification for acceptance, not a web table alone.

Selection boundary

Where S32760 belongs and where to escalate

Grade selection is an environmental decision, not a popularity contest. Review the complete medium, temperature, geometry, fabrication, cleaning and inspection requirements.

Good reasons to evaluate it

01

Offshore piping and manifolds

02

Seawater and desalination equipment

03

Flue-gas and acid process equipment after testing

04

Sour-service components under qualified rules

Reasons to stop and review

01

Calling S32760 and S32750 interchangeable

02

Relying on PRE as the only corrosion criterion

03

Unqualified welding, hot forming or repair cycles

04

Claiming sour-service suitability without hardness and standard review

Fabrication route

Protect properties through cutting, forming and welding

01

Use a qualified S32760/super-duplex welding procedure.

02

Control heat input, interpass, dilution and repairs.

03

Specify ferrite, impact, corrosion and hardness testing.

04

Restore the surface and prevent iron contamination.

Supply definition

Product form changes the applicable requirements

Do not send an RFQ that names only the grade. State form, governing standard, dimensions, tolerances, finish, edge or end condition, quantity, certification and inspection.

Plate, sheet and strip to ASTM A240/A240M
Pipe, tube, fittings and flanges
Bar and forgings
Offshore and process-system components
Certificate checkpoint

Request heat identity, chemical analysis, mechanical results and compliance to the exact product specification. Add PMI, corrosion testing or supplementary examination only when the application requires it.

IMAGE PLACEHOLDER
Super-duplex process componentsReserved for S32760 plate, pipe, fittings or fabricated-component context.
IMAGE PLACEHOLDER
Severe-corrosion serviceReserved for surface, product form and exposure-condition evidence.
IMAGE PLACEHOLDER
Controlled material acceptanceReserved for traceability, dimensions and inspection records.

Interactive selection check

Test S32760 against the controlling question

Procurement FAQ

Questions to close before placing the order

Is S32760 stainless steel magnetic?

Magnetic response depends on microstructure and delivered condition.

Can S32760 replace another grade?

Only after checking the governing standard, composition, mechanical properties, corrosion exposure, fabrication route and certification. A commercial name is not a substitution approval.

Does the table apply to every product form?

No. S32760 contains controlled copper and tungsten and has its own chemistry. Substitution requires purchaser and design approval.

What should a S32760 RFQ include?

Product form, standard and edition, UNS or EN designation, dimensions, tolerances, finish, quantity, service, fabrication, certificate and inspection requirements.

Sources, scope and RFQ

Use traceable grade data, then specify the actual product

Prepared by: Stainless Steel Market Editorial · Technical source review: Website Technical Team · Last updated: 17 September 2026

Source 1

ASTM A240/A240M requirements for UNS S32760 flat product

Source 2

Outokumpu Forta SDX 100 official datasheet

Source 3

NORSOK M-630/MDS requirements when contractually applicable

Source 4

Applicable sour-service, pressure-code and corrosion qualification