A268 TP409 round ferritic tube with route, OD/wall, heat treatment and system basis controlled applications
Round exhaust, hot-gas and mechanical tubing where exact route, OD/wall, treatment and assembly basis are verified.
REQUEST A QUOTE
Send the details you already know. Our team can review the remaining technical points with you.
A268 TP409 round ferritic tube with route, OD/wall, heat treatment and system basis controlled · Grade 409 / S40900
409 round tube requires exact S40900-family identification plus seamless or welded route, OD/wall, heat treatment, tests, ends, bends, joining, service and MTR evidence.

Share product route, service, dimensions, condition and acceptance requirements for review.
Round exhaust, hot-gas and mechanical tubing where exact route, OD/wall, treatment and assembly basis are verified.
Pressure-code or cosmetic wet service without separate code, environment and appearance review.
UNS S40900; EN 1.4512. Verify the ordered product standard and certificate.
Use the controlled product specification, final condition, producer limits, inspection plan and heat/lot certificate for acceptance.
409 / UNS S40900-family composition identifies the alloy family; exact subgrade and MTR govern. Displayed values are grade-family screening references, not finished round tube design values.
| Element | Minimum | Maximum | Unit |
|---|---|---|---|
| C | — | 0.080 | wt % |
| Mn | — | 1.00 | wt % |
| Si | — | 1.00 | wt % |
| P | — | 0.045 | wt % |
| S | — | 0.030 | wt % |
| Cr | 10.50 | 11.75 | wt % |
| Ni | — | 0.50 | wt % |
| Ti | 6 × C | 0.75 | wt % |
| Fe | Balance | — | wt % |
| Property | Minimum | Maximum / range | Unit | Condition / reference |
|---|---|---|---|---|
| Tensile strength | 380 | — | MPa | Annealed 409 product-family screening reference |
| 0.2% yield strength | 170 | — | MPa | Annealed 409 product-family screening reference |
| Elongation | 20 | — | % | Annealed 409 product-family screening reference |
| Rockwell B hardness | — | 95 | HRB | Annealed 409 product-family screening reference |
| Property | Published value | Basis / note |
|---|---|---|
| Density at 20°C | 7.70 g/cm³ | Typical annealed 409 alloy reference. |
| Elastic modulus | 208 GPa | Typical room-temperature ferritic-alloy value. |
| Mean thermal expansion, 20–100°C | 11.0 × 10⁻⁶/K | Typical annealed 409 value. |
| Thermal conductivity at 100°C | 25.8 W/(m·K) | Typical annealed 409 value; finished form is not represented. |
| Specific heat, 0–100°C | 460 J/(kg·K) | Typical annealed 409 value. |
Data note: These values are material-screening references. The governing product specification, ordered condition, dimensions and heat-specific certificate determine acceptance. Review the technical resources for the applicable purchasing basis.

State product standard/edition, seamless or welded route, OD, nominal/minimum wall, length, ovality, straightness, ends, bends and tolerances.
| Duty / item | Starting option | Advantage | Limitation | Alternative / action |
|---|---|---|---|---|
| Exhaust or hot-gas round tubing | A268 TP409 route with exact OD/wall | Low ferritic expansion and familiar tube fabrication | Wet corrosion and appearance are limited | Provide gas chemistry, condensate, temperature and life |
| Bent tubular assembly | 409 round tube with bend route stated | Round section supports predictable bending | Wall thinning, ovality and grain growth can govern | Provide bend radius, tooling and acceptance |
| Pressure-code service | Code-listed material and dimensions verified | Avoids assuming commercial tubing is qualified | A268 alone does not establish system acceptance | Provide code, pressure, temperature and joints |
Product standard: Use current ASTM A268/A268M with A1016/A1016M when TP409 round tubing is covered; state route, OD/wall, treatment and tests.
Finish and condition: Define heat-treated/pickled or bright condition, bore/exterior finish, heat tint, cleaning, markings, end protection and packaging.
Order checks: confirm exact dimensional basis, tolerance, finish, edge/end preparation, quantity and delivery requirements before quotation.
Include OD, wall, straightness, finish, and cut length.
Control the exact product route, dimensions, condition, surface, fabrication, inspection and heat or lot traceability.
| Failure mode | Typical trigger | Control / verification |
|---|---|---|
| Product route omitted | OD/wall tube is ordered using NPS/schedule assumptions. | State A268 or approved route, manufacture, OD/wall, treatment and tests. |
| Bend wall loss or ovality | Only straight-tube dimensions are inspected. | State radius, tooling, thinning, ovality and crack criteria. |
| Commercial tube treated as pressure pipe | Pressure, eddy-current or hydro tests are not invoked clearly. | Verify material, stresses, joints, dimensions and pressure design. |
| Condensate corrosion underestimated | Boiler, exchanger or sanitary duty is assumed covered. | Review condensate, dew point, drainage, heat tint and allowance. |
Inspection and acceptance: Verify exact S40900-family heat analysis, round tube designation, route, dimensions, condition, tests and MTR.
Use current ASTM A268/A268M with A1016/A1016M when TP409 round tubing is covered; state route, OD/wall, treatment and tests.
| Standard / designation | Grade designation | Product scope | Procurement caveat |
|---|---|---|---|
| ASTM A268/A268M, current edition | TP409 / S40900 round ferritic stainless tubing when listed | Seamless or welded nominal-wall ferritic tubing for corrosion-resisting and high-temperature service. | State route, exact OD/wall, heat treatment and hydrostatic or NDE option. |
| ASTM A1016/A1016M, current edition | General requirements for ferritic alloy and stainless tubes | Common manufacture, testing, inspection, dimensions, marking and certification provisions. | A268 requirements prevail; confirm grade, size and supplementary requirements. |
| Approved round-tube drawing and assembly specification | Finished 409 round tube and joined assembly | Controls OD/wall, ovality, straightness, ends, bends, joints and supports. | Commercial dimensions do not establish pressure-code acceptance. |
Use current A268/A268M when TP409 is covered, with A1016 general requirements.
Yes. State route, OD, wall, heat treatment, testing and repair restrictions.
No. System code, listed material, stresses, dimensions and joints need separate verification.
State radius, tooling, seam orientation, thinning, ovality, wrinkles and crack limits.
Condensate, chlorides, deposits, heat tint and surface condition affect appearance and corrosion.
Attach drawing and identify seam, end, and inspection requirements.
Illustrative enquiry: 409 Stainless Steel Round Tube; state subgrade, route, dimensions, condition, service, tests and certificate.
State fluid/gas, temperature, pressure, corrosion, bends, joints and code.
State A268 edition when applicable, TP409 coverage, route, OD/wall, treatment, ends and tests.
Match heat, route, dimensions, treatment, tests and MTR; verify system acceptance separately.
Producer data support alloy screening; controlled standards and heat/lot records determine acceptance.
Not finished-product design allowables.
Verify current-edition grade, route and size coverage.
Drawing, tests and MTR remain controlling.
Separate alloy identity from product route, geometry, condition, service and evidence.
Product-specific review: State exact 409 subgrade, controlled round tube route, dimensions, condition, service, tests and documents.
Continue the specification review with 409 stainless steel grade, 409 seamless tube route, 409 welded tube route, 409 round bar, technical resources.