Skip to main content
Stainless Steel
Market

Plate · Grade 409 / S40930

409 Stainless Steel Plate

409 stainless steel plate is a stabilized ferritic grade considered for automotive exhaust, heat-resistant and fabrication applications. This page uses ATI S40930 sheet/strip data for grade screening; EN 1.4512 is shown only as a 409-family reference, not as an asserted exact cross-equivalence. Confirm the plate UNS, product standard, thickness, condition and certificate.

Review technical resources
Grade: 409 / 1.4512 family reference
Product form: Plate
Order-specific data and limits stated
Replace with an approved product-form photo

Is 409 Plate right for the order?

Stabilized ferritic grade; exact UNS variant and forming/welding procedure govern applicability.

Stabilized ferritic grade; exact UNS variant and forming/welding procedure govern applicability.
Best for

Plate applications

Plate enquiries that identify the 409 HP UNS variant and define forming, weld, temperature and corrosion requirements.

Not recommended without review

Conditions that can exceed the grade margin

Do not treat 409 as chloride-pitting resistant or transfer S40930 data to another 409 variant without checking chemistry and specification.

Material identification

Grade 409

UNS S40930; EN 1.4512 family reference. Verify the ordered product standard and certificate.

409 Plate chemistry and property reference

Chemistry and physical values are S40930 grade references; the mechanical table is explicitly sourced to ATI sheet/strip data. Plate acceptance requires the ordered product specification and MTR.

ATI 409 HP S40930 composition limits are shown as a grade reference. Confirm the ordered plate UNS variant and heat analysis. ATI publishes 380 MPa tensile, 170 MPa yield, 20% elongation and 88 HRB maximum for UNS S40930 sheet/strip. These values are screening references only and are not plate-specific acceptance limits.

Chemical composition by mass

ElementMinimumMaximumUnit
Cr10.5011.70wt %
Si—1.00wt %
Mn—1.00wt %
Ti0.050.75wt %
Ni—0.50wt %
P—0.040wt %
N—0.030wt %
C—0.030wt %
S—0.020wt %
Ti+Cb[0.08+8×(C+N)]0.75wt %
FeBalance—wt %

Mechanical properties

PropertyMinimumMaximum / rangeUnitCondition / reference
Tensile strength380—MPaATI 409 HP sheet/strip, UNS S40930; published minimum. Screening reference for a plate enquiry only.
0.2% yield strength170—MPaATI 409 HP sheet/strip, UNS S40930; published minimum. Screening reference for a plate enquiry only.
Elongation20—%ATI 409 HP sheet/strip, UNS S40930; published minimum. Screening reference for a plate enquiry only.
Hardness—88HRBATI 409 HP sheet/strip, UNS S40930; published maximum. Screening reference for a plate enquiry only.

Typical physical properties

PropertyPublished valueBasis / note
Density7.75 g/cm3ATI current ATI 409 HP sheet product table; UNS S40930 reference.
Mean thermal expansion, 20-100 C10.52 x 10^-6 /CATI 409 HP technical data; typical reference over stated interval, not a design value.
Specific heat at 20 C477 J/(kg K)ATI 409 HP technical data; typical reference.
Thermal conductivity, 20-100 C25.0 W/(m K)ATI 409 HP technical data; typical reference over stated interval.
Elastic modulus at 20 C200 GPaATI 409 HP technical data; typical reference, not a design allowable.
Electrical resistivity60 microohm cmATI 409 HP technical data; typical reference.

Data note: These values are material-screening references. The governing product specification, ordered condition, dimensions and heat-specific certificate determine acceptance. Review the technical resources for the applicable purchasing basis.

Replace with an approved material inspection photo

How to specify 409 Plate

Request exact thickness, width, length, flatness, edge, finish, tolerance and coil/flat delivery form.

Duty / itemStarting optionAdvantageLimitationAlternative / action
Exhaust plate screening409 HP plate with exact UNS variant statedATI documents plate forming and automotive exhaust use.Hot-end temperature and localized corrosion may exceed the grade's suitability.Evaluate a higher-alloy grade against the service conditions.
Variant selectionState UNS S40930 or another required variantPrevents chemistry/stabilization ambiguity.Type 409 naming alone may not identify Ti/Cb limits.Reconcile purchase order, product specification and heat certificate.
Formed part acceptanceDefine thickness, radii, edges and weld criteriaMakes fabrication and inspection basis reviewable.ATI product reference is not a part-specific forming approval.Qualify the process on the actual drawing and service.

Product standard: ATI lists ASTM A240/ASME SA-240 for ATI 409 HP flat product. State the exact UNS variant, edition, plate dimensions, condition, surface, tests and certification.
Finish and condition: Specify the required finish and acceptance criteria; appearance alone does not establish grade or dimensions.

Order checks: confirm exact dimensional basis, tolerance, finish, edge/end preparation, quantity and delivery requirements before quotation.

Where 409 Plate may fit

Ferritic plate for applications where the specified 409 variant, forming route and service environment are suitable.

ATI documents ATI 409 HP for formed plate uses including automotive exhaust components. Suitability depends on exact UNS variant, thickness, temperature, weld route and corrosion exposure.

Automotive exhaust guards or fabricated components

ServiceUse only after confirming the required thickness is available and certified as the ordered plate/flat product.
Starting gradeUNS S40930 or another specified 409 variant
Why it worksThe 409 family has established automotive exhaust use; the cited ATI numeric data are for sheet/strip.
LimitsDo not treat sheet/strip limits as plate acceptance; hot-end service may require a higher-alloy grade.
MaintenanceInspect formed and welded zones and verify heat/lot traceability.

Formed enclosures or equipment components

ServiceDefine thickness, bend radii, edge condition, weld route and environment before selecting the product form.
Starting grade409 variant under an explicitly accepted flat-product route
Why it worksThe ferritic 409 family offers useful formability and oxidation resistance for suitable environments.
LimitsPlate availability and thickness-specific forming behavior require mill confirmation.
MaintenanceInspect cut edges, formed radii, weld heat-affected zones and deposits.

Heat-resistant equipment components

ServiceScreen only after checking temperature, process medium, fabrication and inspection requirements.
Starting gradeExact 409 UNS variant and certified product form
Why it worksProducer literature documents oxidation-resistant 409-family service, primarily using sheet/strip and tubing examples.
LimitsThe cited source does not qualify a specific plate product for every process-fluid environment.
MaintenanceReview corrosion exposure, weld requirements, dimensions and certificate.

Risks to control for 409 Plate

Failure modeTypical triggerControl / verification
409 UNS variant is unspecifiedA240 Type 409 is ordered without stating required variant or supplementary chemistry.Name the UNS designation and confirm carbon/Ti/Cb stabilization against the heat certificate.
Plate and plate guidance are mixedThin-plate data are applied to thick-gauge plate or vice versa.Match thickness and product form to the specific source table and purchase specification.
Chloride or hot-end service is underestimatedNominal 11% chromium is treated as immunity to localized corrosion or high-temperature oxidation.Assess actual medium and temperature; ATI notes limited chloride pitting/crevice resistance and higher-alloy grades may be needed for hot zones.

Inspection and acceptance: Check UNS S40930 designation, heat certificate, Ti/Cb analysis, thickness/width, surface and required tests against the purchase order.

409 Plate standards and designation

State the exact UNS variant, plate product specification, edition, dimensions, condition, tests and certification. EN 1.4512 is a 409-family reference and must not be treated as an automatic exact equivalent to UNS S40930.

Standard / designationGrade designationProduct scopeProcurement caveat
ASTM A240/A240M409 / UNS S40930Plate thickness, cut size and supply condition.Order the exact S40930 variant and stabilization limits rather than generic 409 chemistry.
ASTM A480/A480M409 plate general requirementsFlat-product dimensions, workmanship, finish and inspection where invoked.Define flatness, machining stock and any through-thickness examination.

Questions about 409 stainless steel Plate

Which 409 grade do these numbers describe?

ATI states the displayed plate chemistry and properties are for UNS S40930; Ti/Cb ranges vary for S40910 and S40920.

What mechanical limits are published for S40930 plate?

ATI lists tensile strength at least 380 MPa, yield strength at least 170 MPa, elongation at least 20%, and hardness no more than 88 HRB.

Can 409 plate be substituted for 304?

Not without reviewing corrosion, forming, weld, temperature and service requirements; ferritic 409 and austenitic 304 are different alloy families.

Does this page specify plate thickness or finish?

No stock dimensions are asserted here. Put thickness, width, length, finish, tolerances, quantity and certificate requirements in the enquiry.

What should be checked on receipt?

Match UNS grade, heat/lot certificate and ordered specification; inspect dimensions, finish, condition, markings and agreed tests.

Example: prepare a 409 Plate enquiry

Illustrative buying case: a fabricator requests S40930 plate with drawing dimensions, finish, tolerances and certificate requirements.

Illustrative buying case: a fabricator requests S40930 plate with drawing dimensions, finish, tolerances and certificate requirements.

Identify variant

UNS grade and stabilization

State Type 409/UNS variant, ASTM A240 edition, and any Ti/Cb or carbon requirements.

Define plate supply

Gauge, finish and forming basis

Specify thickness, width, flatness, edge, finish, tolerances, delivery form, quantity and certificate.

Confirm service fit

Weld, temperature and corrosion review

Provide service environment and fabrication route; agree inspection criteria for formed and welded areas.

Acceptance: Check UNS S40930 designation, heat certificate, Ti/Cb analysis, thickness/width, surface and required tests against the purchase order.

Official 409 Plate data source

ATI S40930 sheet/strip data support grade screening. ASTM A240 supplies the flat-product route, but the producing mill must confirm plate availability, thickness-specific requirements and certification.

01

ATI 409 HP product data

Sheet values support screening only; verify plate form, thickness and heat certificate.

02

ASTM A240/A240M

Confirm exact UNS variant, ordered edition, plate condition and supplements.

03

ASTM A480/A480M

Use when invoked by the accepted product specification or purchase order.

Request a 409 Plate quote

Send the grade, standard edition, dimensions, finish, condition, quantity, destination and certificate requirements for a traceable quotation.

  • MaterialGrade 409; UNS S40930; EN 1.4512 family reference
  • Product formPlate
  • DimensionsRequest exact thickness, width, length, flatness, edge, finish, tolerance and coil/flat delivery form.
  • Standard and conditionATI lists ASTM A240/ASME SA-240 for ATI 409 HP flat product. State the exact UNS variant, edition, plate dimensions, condition, surface, tests and certification.
  • Service / fabricationATI documents ATI 409 HP for formed plate uses including automotive exhaust components. Suitability depends on exact UNS variant, thickness, temperature, weld route and corrosion exposure.
  • Inspection requirementsCheck UNS S40930 designation, heat certificate, Ti/Cb analysis, thickness/width, surface and required tests against the purchase order.

Product-specific review: Check UNS S40930 designation, heat certificate, Ti/Cb analysis, thickness/width, surface and required tests against the purchase order.