202 stainless steel coil is UNS S20200 flat-rolled material delivered as hot- or cold-rolled coil. Specify the sheet-or-strip basis, ASTM A240/A480 or A666, thickness, width, edge, finish, temper, coil geometry and MTR.
Share the service environment, dimensions and acceptance requirements for review.
Continuous roll forming, stamping and appliance production where coil geometry and processing condition are controlled.
Orders that omit sheet-versus-strip basis, temper, edge, finish, coil ID/OD or weight, or automatic substitution for 304.
UNS S20200; EN 1.4373. Verify the ordered product standard and certificate.
All four flat-product pages share S20200 chemistry and typical physical values. Product form, dimensions, finish, temper and acceptance evidence remain order-specific.
Jindal J202 / UNS S20200 producer chemistry limits are shown. The ordered standard and heat analysis control acceptance. Jindal J202 ASTM A240 annealed flat-product minima are shown. Cold-worked product needs temper- and thickness-specific requirements.
| Element | Minimum | Maximum | Unit |
|---|---|---|---|
| C | — | 0.15 | wt % |
| Mn | 7.50 | 10.00 | wt % |
| Si | — | 1.00 | wt % |
| P | — | 0.060 | wt % |
| S | — | 0.030 | wt % |
| Cr | 17.00 | 19.00 | wt % |
| Ni | 4.00 | 6.00 | wt % |
| N | — | 0.25 | wt % |
| Fe | Balance | — | wt % |
| Property | Minimum | Maximum / range | Unit | Condition / reference |
|---|---|---|---|---|
| Tensile strength | 620 | — | MPa | Annealed S20200 flat product; confirm thickness and specimen applicability |
| 0.2% yield strength | 260 | — | MPa | Annealed S20200 flat product |
| Elongation | 40 | — | % | Annealed S20200 flat product |
| Hardness | — | 241 | HB | Annealed S20200 flat product |
| Property | Published value | Basis / note |
|---|---|---|
| Density | 7.85 g/cm³ | Venus Wires Grade 202 typical reference. |
| Elastic modulus | 200 GPa | Venus Wires Grade 202 typical reference. |
| Thermal conductivity at 100°C | 16.2 W/(m·K) | Venus Wires Grade 202 typical reference. |
| Electrical resistivity at 20°C | 0.74 µΩ·m | Venus Wires Grade 202 typical reference. |
| Specific heat | 500 J/(kg·K) | Venus Wires Grade 202 typical reference. |
Data note: These values are material-screening references. The governing product specification, ordered condition, dimensions and heat-specific certificate determine acceptance. Review the technical resources for the applicable purchasing basis.
State thickness, width, tolerances, mill/slit edge, finish, temper, coil ID/OD, maximum coil weight, weld policy, interleave and packaging.
| Duty / item | Starting option | Advantage | Limitation | Alternative / action |
|---|---|---|---|---|
| General coil in dry indoor service | S20200 with product-specific dimensions and condition | Cost-conscious austenitic option with useful strength | Lower corrosion margin than 304 | 304 when service or fabrication margin requires |
| Cold-worked high-strength part | Temper-specific 202 coil | Higher strength from cold work | Lower ductility and more springback | 301/201/202 route after forming trials |
| Wet, exterior or chloride exposure | Reassess 202 before ordering | Avoids unsupported substitution | Higher-alloy material may be required | 304/316 or project-approved grade |
Product standard: ASTM A240 covers plate, sheet and strip; A480 supplies general flat-product requirements; A666 covers annealed or cold-worked austenitic products.
Finish and condition: Name hot-rolled, 2D, 2B, BA or other finish; define surface protection, telescoping, edge damage and allowable coil defects.
Order checks: confirm exact dimensional basis, tolerance, finish, edge/end preparation, quantity and delivery requirements before quotation.
Send the drawing, environment and fabrication route for review.
Select the exact product condition after reviewing environment, forming, joining, surface and inspection requirements.
| Failure mode | Typical trigger | Control / verification |
|---|---|---|
| Wrong product basis | Coil is ordered without sheet or strip requirements | State the governing product form and standard edition. |
| Temper mismatch | Annealed mechanics are applied to cold-worked coil | Name the temper and mechanical table. |
| Coil-build problem | ID, OD, weight or telescoping limits are absent | Define coil geometry and handling limits. |
| Traceability loss after slitting | Child coils lose parent heat identity | Maintain parent-child lot records. |
Inspection and acceptance: Verify S20200 chemistry, product basis, dimensions, edge/finish, temper-specific mechanics, coil build, ID/OD/weight, markings and MTR.
State UNS S20200, product form, exact standard edition, dimensions, condition and certificate. Treat EN 1.4373 as a separate procurement route.
| Standard / designation | Grade designation | Product scope | Procurement caveat |
|---|---|---|---|
| ASTM A240/A240M-26 | Type 202 / UNS S20200 | Stainless steel plate, sheet and strip; the ordered dimensions determine the applicable flat-product route. | State product form, dimensions, finish, condition, test requirements and heat/lot certificate. |
| ASTM A480/A480M-25b | General flat-rolled requirements | General requirements for stainless plate, sheet and strip. | Invoke applicable tolerances, flatness, finish, inspection, marking and packaging. |
| ASTM A666/A666M-24 | Annealed or cold-worked Type 202 | Annealed or cold-worked austenitic sheet, strip, plate and flat bar. | State annealed or cold-worked condition and thickness-specific mechanical acceptance. |
| EN 10088-2 / 1.4373 | X12CrMnNiN18-9-5 / 1.4373 | European stainless flat-product route. | Treat as a separate route; do not mix EN and ASTM chemistry or mechanics without approval. |
No. S20200 has different manganese, chromium and nickel limits; verify the UNS and heat analysis.
No. Corrosion resistance, forming, welding and code requirements must be reviewed before substitution.
Chemistry and typical physical properties belong to the S20200 grade. Product form changes dimensions, finish, condition, standards and acceptance tests.
No. Cold work increases strength and reduces ductility; order the exact temper and applicable mechanical table.
State UNS S20200, product standard and edition, dimensions, surface/finish, condition, tests, quantity, packaging and MTR.
Ready to quote? Send dimensions, quantity, destination and inspection needs.
Specify UNS S20200 coil with the applicable product standard and edition, dimensions, finish/surface, condition, mechanical tests, quantity, packaging and heat/lot certificate.
State S20200, coil, environment, fabrication and governing code.
State thickness, width, tolerances, mill/slit edge, finish, temper, coil ID/OD, maximum coil weight, weld policy, interleave and packaging.
Check chemistry, mechanics, dimensions, surface, heat/lot identity and certificate.
Producer data and current product-standard scope support these references. The purchase specification and heat/lot certificate control acceptance.
The ordered edition and MTR control acceptance.
State the exact product form, dimensions, finish and condition.
Invoke applicable tolerances, marking and packaging.
Cold-worked product needs temper-specific acceptance.
A complete enquiry connects alloy identity to product form, dimensions, condition and inspection.
Product-specific review: State thickness, width, tolerances, mill/slit edge, finish, temper, coil ID/OD, maximum coil weight, weld policy, interleave and packaging. Include quantity, destination, tests and MTR.