Skip to main content
Stainless Steel
Market

Fittings · Grade 201 / S20100

201 Stainless Steel Fittings

Type 201 / UNS S20100 fittings are a specification-first purchase. Identify whether the item is decorative, fabricated or pressure-piping equipment before comparing offers. No universal 201 fitting size range or pressure rating is asserted; confirm the exact material route, drawing, finish, tests and certificate.

Review technical resources
Grade: 201 / 1.4372
Product form: Fittings
Order-specific data and limits stated

Need Fittings in a defined size and condition? Send the drawing and purchase basis.

Grade identity does not define fitting geometry, rating or acceptance. Forming, welds, ends and the component standard control.
Best for

Fittings applications

Drawing-defined non-pressure fittings after review of material, geometry, joining route and environment.

Not recommended without review

Conditions that can exceed the grade margin

Pressure service selected from a generic 201 label without a governing standard and confirmed grade coverage.

Material identification

Grade 201

UNS S20100; EN 1.4372. Verify the ordered product standard and certificate.

201 Stainless Steel Fittings chemistry and property reference

No universal Type 201 fitting mechanical or pressure limits are stated here. Verify exact grade coverage, product specification, manufacturing route and heat/lot test records. Chemical composition is an ATI 201 HP alloy reference; verify the ordered material specification and heat certificate.

ATI 201 HP publishes Type 201/S20100 chemistry per ASTM A240. Alloy reference only; the heat certificate governs. No universal Type 201 fitting mechanical or pressure limits are stated here. Verify exact grade coverage, product specification, manufacturing route and heat/lot test records.

Chemical composition by mass

ElementMinimumMaximumUnit
C—0.15wt %
Mn5.507.50wt %
Si—1.00wt %
P—0.060wt %
S—0.030wt %
Cr16.0018.00wt %
Ni3.505.50wt %
N—0.25wt %
FeBalance—wt %

Typical physical properties

PropertyPublished valueBasis / note
Density7.86 g/cm³ATI 201 HP typical alloy reference; not a product acceptance/design limit.
Elastic modulus193 GPaATI 201 HP typical alloy reference; not a product acceptance/design limit.
Mean expansion, 20–100°C16.6 × 10⁻⁶/KATI 201 HP typical alloy reference; not a product acceptance/design limit.
Thermal conductivity16.3 W/(m·K)ATI 201 HP typical alloy reference; not a product acceptance/design limit.
Specific heat502 J/(kg·K)ATI 201 HP typical alloy reference; not a product acceptance/design limit.

Data note: These values are material-screening references. The governing product specification, ordered condition, dimensions and heat-specific certificate determine acceptance. Review the technical resources for the applicable purchasing basis.

No verified stock range is stated. Provide fitting type, drawing/size, connection, dimensions, finish, quantity and destination; confirm capability by quote.

Duty / itemStarting optionAdvantageLimitationAlternative / action
Non-pressure connectorDrawing-defined fittingGeometry can match assemblyNo generic ratingProvide drawing and service.
Pressure fittingCode-listed materialDefined rating route201 coverage not assumedCheck grade in active code.
Decorative connector201 after exposure reviewMild-service screeningFinish/welds governSpecify finish and cleaning.

Product standard: ASTM A403/A774 describe fitting standards with specified grade scope; neither title alone proves Type 201 coverage or pressure acceptance.
Finish and condition: Define finish, edge/burr, cleaning and packaging requirements in the drawing or order.

Order checks: confirm exact dimensional basis, tolerance, finish, edge/end preparation, quantity and delivery requirements before quotation.

201 Fittings applications and limits

Share service conditions and acceptance requirements for this Fittings application.

Separate tube accessories from pressure fittings. State mating product, joint method, pressure, temperature, fluid and cleaning exposure.

Architecture

ServiceFinish and weather exposure.
Starting grade201/S20100 after product-form review
Why it works201 may be reviewed for a non-pressure connector.
LimitsNo generic corrosion/load rating.
MaintenanceSet finish and maintenance.

Equipment

ServiceGeometry and loads govern.
Starting grade201/S20100 after product-form review
Why it worksDrawing-defined S20100 part may be screened.
LimitsGrade is not a design allowable.
MaintenanceProvide loads and inspection.

Process line

ServicePressure, temperature and fluid govern.
Starting grade201/S20100 after product-form review
Why it worksUse code-listed route if pressure-containing.
LimitsDo not assume A403/A774 coverage.
MaintenanceName code, grade and class.

201 Fittings risks to control

Failure modeTypical triggerControl / verification
Wrong ratingGrade mistaken for qualificationCheck active component specification.
Joint leakEnd or weld undefinedSpecify connection and inspection.
Crevice corrosionDeposits or cleaners at jointsReview exposure and finished assembly.

Inspection and acceptance: Name the fitting standard and edition; confirm grade coverage, dimensions, rating basis, tests, marking and heat/lot certificate.

Standards and grade designation

ASTM A403/A774 describe fitting standards with specified grade scope; neither title alone proves Type 201 coverage or pressure acceptance.

Standard / designationGrade designationProduct scopeProcurement caveat
ASTM A403/A403MCheck grade listWrought pressure fittingsDo not infer S20100 coverage.
ASTM A774/A774MSpecified gradesAs-welded fittingsLimited scope; not full pressure rating.
ASTM A240/A240MFlat productsPlate, sheet, stripNot finished fitting certification.

Questions about 201 Stainless Steel Fittings

Are 201 fittings pressure-rated?

Not by grade name. Verify exact material and grade coverage in the governing code.

Does A403 prove a 201 fitting compliant?

No. Check the active edition's grade list.

Can I buy decorative 201 fittings?

Potentially, after drawing, finish, service and capability are confirmed.

What should an RFQ include?

Type, drawing, connection, mating product, service, finish, tests and certificate.

Does chemistry certify a fitting?

No. The heat certificate and ordered specification govern.

Example 201 Fittings RFQ

Send quantity, destination, dimensions and inspection requirements.

Define fitting

Part and connection

Identify type, drawing, mating end and pressure/non-pressure duty.

Set design basis

Service conditions

State code, pressure, temperature and fluid.

Verify acceptance

Grade and tests

Confirm standard coverage, inspection and traceability.

Acceptance: Name the fitting standard and edition; confirm grade coverage, dimensions, rating basis, tests, marking and heat/lot certificate.

Sources for 201 Fittings data

References establish alloy identity or standard scope; the ordered specification and lot certificate control acceptance.

01

ATI 201 HP product specifications by form

Alloy/substrate reference only; finished-product acceptance remains subject to the ordered standard and heat/lot certificate.

02

ASTM A403/A403M-26

ASTM A403/A774 describe fitting standards with specified grade scope; neither title alone proves Type 201 coverage or pressure acceptance.

03

ASTM A774/A774M-26

ASTM A403/A774 describe fitting standards with specified grade scope; neither title alone proves Type 201 coverage or pressure acceptance.

Request a 201 Fittings quote

Send product form, drawing, dimensions, service conditions, governing standard, finish, tests, quantity and destination.

  • MaterialGrade 201; UNS S20100; EN 1.4372
  • Product formFittings
  • DimensionsNo verified stock range is stated. Provide fitting type, drawing/size, connection, dimensions, finish, quantity and destination; confirm capability by quote.
  • Standard and conditionASTM A403/A774 describe fitting standards with specified grade scope; neither title alone proves Type 201 coverage or pressure acceptance.
  • Service / fabricationSeparate tube accessories from pressure fittings. State mating product, joint method, pressure, temperature, fluid and cleaning exposure.
  • Inspection requirementsName the fitting standard and edition; confirm grade coverage, dimensions, rating basis, tests, marking and heat/lot certificate.

Product-specific review: Name the fitting standard and edition; confirm grade coverage, dimensions, rating basis, tests, marking and heat/lot certificate.